Calculator
Half-value layer
Dose rate behind solid shielding, calculated from the half-value layers (HVL) of the isotope in lead, steel or concrete.
Without shieldingmSv/h
LeadmSv/h
SteelmSv/h
ConcretemSv/h
Method
Ḣ = Ḣ₀ × 2^(−t / HVL)
Ḣ₀ = A × 0.037 × Γ / d²
- Ḣ₀ — dose rate without shielding in mSv/h
- t — shield thickness in mm
- HVL — half-value layer in mm for the material
- Γ — gamma constant in mSv·m²/(h·TBq)
- d — source-to-shield distance in m
HVL values used — Ir-192: lead 4 mm, steel 13 mm, concrete 60 mm. Se-75: 1 / 8 / 30 mm. Co-60: 13 / 20 / 100 mm. These are approximations for a broad beam: scatter and build-up are ignored, so the real dose rate behind the shield is understated. Measure before working behind shielding.
Indicative result — check it against your authorisation and your dosimetry.